Quality Light-Resistant Amber IV Set TPU Inner Layer Precision Filter Options factory
Quality Light-Resistant Amber IV Set TPU Inner Layer Precision Filter Options factory
Quality Light-Resistant Amber IV Set TPU Inner Layer Precision Filter Options factory
Quality Light-Resistant Amber IV Set TPU Inner Layer Precision Filter Options factory

Light-Resistant Amber IV Set TPU Inner Layer Precision Filter Options

Light-Resistant Amber IV Set TPU Inner Layer Precision Filter Options
Basic Properties
Country Of Origin
China
Certificate
CE ISO
PRODUCT MODEL
Light-Resistant Amber IV Set
Trading Properties
MOQ
100000
Payment Method
T/T
Product Summary

Light-resistant amber IV set for light-sensitive solutions. Triple-layer light-resistant tubing and drip chamber; TPU inner layer shields solution, air-liquid interface stays visible. Standard, precision-filter and flow-control versions; TOTM options and accessories.

Product Details
Highlight:

Light-resistant amber IV set

,

Triple-layer protection Light-resistant amber IV set

,

TPU inner layer Light-resistant amber IV set

Product Name: Light-Resistant Amber IV Set
Product Alias: Light-Protected IV Infusion Set
Light Protection: Triple-Layer Amber Structure
Tube Material: TPU Inner Layer / Non-PVC
Filter Options: Standard / Precision Filter
Precision Filter: 1.2 / 2.0 / 3.0 / 5.0 μm
Flow Control: Standard / Micro Flow Control
Needle: With Disposable IV Needle
Needle Diameter: 0.45–1.2 Mm
Sterilization: EO Sterilized
Product Description

Light-Resistant Amber IV Set TPU Inner Layer Precision Filter Options

Product Overview

Light-Resistant Amber IV Set is designed for intravenous administration of medicinal solutions that require protection from light during infusion. The tubing and drip chamber feature a triple-layer light-resistant structure, with a TPU inner contact layer that separates the medicien solution from the light-shielding layer. This configuration is designed to maintain stable light protection while allowing healthcare professionals to observe the air-liquid interface during infusion. Different configurations are available, including standard, precision-filter and flow-control versions, with TOTM material options and selectable accessories for different clinical and procurement requirements.

Key Advantages

Feature Benefit
Triple-Layer Light Protection Helps maintain stable light shielding during the product service life
TPU Inner Layer Non-PVC medicien-contact layer designed to isolate the solution from the light-shielding layer
High Light Blocking Tubing and drip chamber provide high light-shielding performance
Clear Observation Supports visual observation of the air-liquid interface
Precision Filtration Multiple precision filer pore sizes available
Multiple Configurations Standard, precision filter pore sizes available
Flexible Flow Control Flow-setting configuration can support controlled infusion rates
Optional Accessories Latex tube and infusion dressing can be selected according to requirements

Product Variants

Light-Resistant IV Set with Needle

The standard light-resistant configuration is intended for routine intravenous infusion of light-sensitive medicinal solutions. It uses the amber triple-layer structure and is available with needle diameters from 0.45 mm to 1.2 mm. Customers can select the required configuration and accessories according to their application.

Light-Resistant Amber IV Set TPU Inner Layer Precision Filter Options

TOTM Light-Resistant IV Set with Needle

The TOTM configuration provides an alternative material option for customers with specific material requirements. It retains the triple-layer light-resistant structure and is available with multiple needle specifications. Optional latex tubing and infusion dressing can be selected individually or together.

Light-Resistant Amber IV Set TPU Inner Layer Precision Filter Options

TOTM Precision Filter Light-Resistant IV Set with Needle

This configuration combines light protection with precision filtration. Multiple filter pore sizes are available, including 1.2 μm, 2.0 μm, 3.0 μm and 5.0 μm, depending on the selected configuration. Needle diameter, effective length, wall type and bevel design can also be selected.

Light-Resistant Amber IV Set TPU Inner Layer Precision Filter Options

Optional Flow-Control Configuration

A flow-setting configuration is available for applications requiring more controlled infusion rates. The specified flow adjustment range is 5–250 mL/h, providing an additional option for infusion rate management.

Optional Accessories

Customers can configure the set with latex tubing and/or an infusion dressing according to their purchasing and application requirements. These accessory choices are presented as configuration options rather than internal model codes.

Light-Resistant Amber IV Set TPU Inner Layer Precision Filter Options

Applications

  • Intravenous administration of medicinal solutions
  • Infusion of light-sensitive medicines
  • Hospital and clinical IV therapy
  • Medicien infusion requiring light protection
  • Applications requiring precision filtration
Related Products