BPA-Free Low-Flux PES Hollow Fiber Dialyzer for Gentle Initial and Sensitive Patient Dialysis
It is a low‑flux hemodialyzer with BPA‑free PES membrane, wavy fiber design, and patent super‑smooth end‑face cutting technology. Suitable for patients new to dialysis, elderly with hypotension, and hypoalbuminemia – gentle clearance with minimal albumin loss.
Low-Flux Hemodialyzer
,Acute Kidney Injury Low-Flux Hemodialyzer
,Hemodynamic Stability Low-Flux Hemodialyzer
Low-Flux PES Hollow Fiber Dialyzer
Key Features
-
Gentle Clearance – Small molecular toxin removal with minimal albumin loss
-
Hemodynamic Stability – Gradual fluid removal, reduced hypotension risk
-
Low Blood Flow Tolerability – Suitable for poor vascular access
-
Wavy Fiber Design – Enhanced mechanical strength with thorough dialysate perfusion
-
Super‑Smooth End‑Face Cutting – Reduces clotting, ensures complete blood return
-
Seamless Welding – Durable integrated construction
-
BPA‑Free – PES membrane + PP housing, no Bisphenol A

| Hollow Fiber Hemodialyzer (PF Series) — In Vitro Performance Specifications | ||||||||||||||||||||||
| Parameter | B-14PF | B-15PF | B-16PF | B-17PF | B-18PF | B-19PF | B-20PF | |||||||||||||||
| Blood Flow Rate(mL/min) | 200 | 300 | 400 | 200 | 300 | 400 | 200 | 300 | 400 | 200 | 300 | 400 | 200 | 300 | 400 | 200 | 300 | 400 | 200 | 300 | 400 | |
| Solute Clearance (mL/min) | ||||||||||||||||||||||
| Urea | 189 | 251 | 281 | 190 | 255 | 285 | 191 | 259 | 290 | 192 | 262 | 295 | 193 | 266 | 300 | 194 | 270 | 305 | 195 | 274 | 311 | |
| Creatinine | 180 | 232 | 260 | 181 | 238 | 267 | 183 | 244 | 275 | 184 | 250 | 281 | 186 | 256 | 287 | 187 | 261 | 293 | 189 | 267 | 299 | |
| Phosphate | 179 | 228 | 267 | 182 | 234 | 273 | 185 | 240 | 280 | 187 | 245 | 286 | 190 | 250 | 292 | 191 | 255 | 298 | 192 | 260 | 305 | |
| Vitamin B₁₂ | 114 | 132 | 142 | 118 | 140 | 150 | 123 | 148 | 158 | 126 | 155 | 166 | 130 | 162 | 175 | 134 | 169 | 181 | 138 | 177 | 188 | |
| Other Specifications | ||||||||||||||||||||||
| Ultrafiltration Rate(mL/h) | 2100 | 2200 | 2300 | 2400 | 2600 | 2700 | 2900 | |||||||||||||||
| Effective_Surface_Area(m²) | 1.4 | 1.5 | 1.6 | 1.7 | 1.8 | 1.9 | 2.0 | |||||||||||||||
Test Conditions
Clearance: QD = 500 mL/min; temperature 37 °C ± 1 °C; QF = 10 mL/min.
Ultrafiltration Rate: test fluid = anticoagulated bovine plasma, protein concentration 60 g/L ± 5 g/L; QB = 300 mL/min; TMP = 100 mmHg.
Standard: YY 0053:2016
FAQ
Q1: What is a Low‑Flux dialyzer and which patients is it suitable for?
A low‑flux dialyzer has lower hydraulic permeability and is primarily used for standard hemodialysis. It is particularly suitable for:
-
Patients newly initiated onto dialysis
-
Elderly patients with poor vascular access or hypotension
-
Patients with hypoalbuminemia (plasma albumin < 30 g/L)
-
Temporary or transitional dialysis patients
Final selection should be made by the treating physician based on dialysis vintage, comorbidities, vascular access, nutritional status, and regular monitoring of β₂‑MG and PTH levels.
Q2: What is the difference between Low‑Flux and High‑Flux dialyzers?
| Aspect | Low‑Flux | High‑Flux |
|---|---|---|
| Primary Patient Group | New dialysis, elderly, hypotension, hypoalbuminemia | Long‑term ESRD, high β₂‑MG/PTH |
| β₂‑MG Clearance | Minimal | Significant |
| Albumin Loss | Minimal | May occur |
| Hemodynamic Stability | Excellent | Variable |
| Blood Flow Requirement | Low flow tolerated | Standard flow |
Choose Low‑Flux when gentle clearance and hemodynamic stability are priorities; choose High‑Flux when middle molecule clearance is needed.
Q3: What do the model numbers mean?
The number indicates the effective membrane surface area – e.g., B‑16PF = 1.6 m². The suffix “PF” denotes the Low‑Flux series. Choose based on patient size and clearance needs. 1.4–1.6 m² for smaller patients.
Membrane area 1.7–1.8 m² for standard patients; 1.9–2.0 m² for larger patients or higher clearance needs.
Q4: What is the super‑smooth end‑face cutting technology?
It ensures a smooth, uniform cutting surface on the hollow fiber ends. This reduces blood clotting at the fiber entry points and enables more complete blood return at the end of treatment – minimizing blood loss and reducing the risk of residual blood in the dialyzer.
Q5: What is the wavy hollow fiber design?
The wave‑shaped fiber design enhances mechanical strength, reduces fiber breakage risk, and ensures thorough dialysate perfusion around each fiber for consistent treatment performance.